Sinarum STC-9100 Foedus Panel Defrost Thermostat - pretium Lupum, usor manualis, fermentum, wiring diagram, Ponens ducem video, alterum
STC-9100 thermostat digital defrosts designatus est ad regendum Refrigerans & Defrost & Externus Alarm potentia copia status per 3 output dispositos et 2 NTC sensoriis. Typice aptum est locus temperatus ultra-humilis freezeri, qui facile frigescit in evapora- torem suum.
Minimum ordo moles: CC USD
STC-9100 Thermostat Features
Per 3 output dispositos et 2 NTC sensores, STC-9100 thermostatae propriae lineae inferiores possidet.
- Temperamentum paro-punctum (-50 .0 ad 500.0 ) et hysteresis ad scopum temperatum range determinare; Maximum autem et humile limitem ad Temperaturae Set-punctum praesto est;
- Temperantia refrigerationem per temperiem et moras tempus editabile;
- Temperantia et mora editable temperie defrosting per tempus, et artificiosa coacta defrost praesto;
- Supple aqua fluens tempus editabile;
- Defrost sensorem temperatura permanentem ostensionem ostensionis est rem deduceretur;
- Metus per errorem codicem in ostentatione et stridore clamoribus ac terrorem nimis temperatum munus debilitari potest;
- Temperatus terrorem moderari freezer locus per tempus et temperies;
- Temperatus terrorem moderari defrosting unitas temporis ac tortor.
- control the terror output modus et vagandi juxta buzzer terror.
features I ad VIII sicut idem quod STC-9200
STC 9100 temperatus controller Benefits
- 3 modos erecti praesto sunt in STC-9100 digital defrost thermostat;
- both the room temp and the evaporator temperatus could trigger alarming, and individual options for setting them;
- Separatim administrator et menu usoris, facile operari pro usoribus, et punctum praefixum limitari potuit in menu lockable admin;
- Optiones sufficiens ad occasum defrostionis, sicut aqua destillans Tempus, tempus diutinum defringens, temporis intervallum defrosting, Defrosting Sistere Temperature, et modum defrost cycli Comitis.
- Batch upload / download configure notitia ad arbitrium auxilium per Exemplar Key
- Magnum et clarum DUXERIT propono cum solutione 0.1°C;
- 2 pieces IMPERVIUS NTC sensorem temperatum (2 m longitudo funis sensoris) cum accuratione ±1°C;
Front Panel of STC-9100 Defrost Thermostat
Wiring Diagram STC-9100 Defrost Controller
- Portus 1#: Viva wiring ex potestate initus erit output ad onera ex aliis portubus (#2/3/4) si condiciones perventum est,Periculosum est si filum iniuriae coniungas.
- Portus 2#: Nullam ad iungendum compressorem ad generandum altum pressuram calidum aerem, faciet evaporatorem temperatum depressum;
- port 3#: Nullam ad wiring defluentem unitatem evaporatoris;
- port 4#: Nullam ad terrorem output, hoc unicum consilium permittit vigilantium externum wiring qui extra domum ambulationem-in freezer;
- port 5# & 6#: input power for STC-9100 working;
- portum VII #: De NTC Sensorem metiendi instant locus temperatus
- Portus 8: Co-punctum pro duali temp NTC Sensor
- port 9#: The NTC Sensor for metiendis instant temperies defrosting unit on the evaporator
- Exemplar-clavem: Mini USB sectam portum ad molem configurant moderatoris, diversae ab Ako temperaturae ostentationem moderatoris, qua utuntur domini moderatoris ad unitates servi administrandi.
Munus Menu of STC 9100 Defrost Controller
In codice EN et F codice versionis utraque in promptu sunt.
Cate. | EN Code | F Code | Officium | Min | Max | Default | Unitas | Menu Level | |
---|---|---|---|---|---|---|---|---|---|
Temp. | SET | F01 | SP (Temperate Set-Point) | LS | US | -5 | °C | User Menu | |
HY | F02 | Temperature Hysteresis / Differentia Redi | 1 | 25 | 2 | °C | |||
US | F03 | Superior modus for SP | SET | 50 | 20 | °C | Admin Menu | ||
LS | F04 | Lower terminus for SP | -50 | SET | -20 | °C | |||
AC | F05 | Mora Tempus est Compressor Mora tempus defrosting (modo scelerisque aeris modus) | 0 | 50 | 3 | Min | |||
Defr. | IDF | F06 | Defrost | Cycle / Intervallum Tempus | 0 | 120 | 6 | Hora | |
MDF | F07 | Tempus diuturnum | 0 | 255 | 30 | Min | |||
DTE | F08 | Subsisto Temperature | -50 | 50 | 10 | °C | |||
FDT | F09 | Aqua madens Tempus | 0 | 100 | 2 | Min | |||
TDF | F10 | Modus Defrosting: EL: defrost per electrica-calefactionem; HTG: defrost a scelerisque aerem | EL | HTG | EL | ||||
DCT | F11 | Modus computat defrost cyclus; RT: Cumulative time from controlers on; COH: Cumulativo tempore compressor laborat. | RT | COH | RT | ||||
DFD | F12 | Exhibe modum cum defrosting: RT: Cella sensorem temperatura ostendit; IT: Ostendit evaporator sensorem temperatus (perdurans X min cum defrosting super) | RT | IT' | RT | ||||
Alarm | DMO | F13 | Terrorem output options: NC: N/A, interdictum; AC: sequere, BOMBINATOR, urge aliquem clavem sistere; AA: sequere, BOMBINATOR, quiritare, nisi fixum omnes errores. | NC | AC | NC | |||
ELL | F14 | Evaporator Sensor Temperature ad Trigger Alarm | Lower Low | -50 | ELU | -50 | °C | ||
EOD | F15 | Tempus mora | 0 | 255 | 0 | Min | |||
ELU | F16 | Superioris limitis | ELL | 50 | 50 | °C | |||
ALU | F17 | Locus sensorem Temperature ad Trigger Alarm | Superioris limitis | OMNIS | 50 | 50 | °C | ||
OMNIS | F18 | Lower Low | -50 | ALU | -50 | °C | |||
ALD | F19 | Tempus mora | 0 | 99 | 15 | Min | |||
Calib. | OT | F20 | Calibration caliditas | -10 | 10 | 0 | °C |
Ut ac posuere tortor?
Locus temperatus definitus est ex "F1" ad "F1 + F2" (ex "SET" ad "SET + HY");
Eas in usore interface aut Admin Interface sistere potes, infra est the modum administratoris.
- Intra Admin Interface: clavis et clavis [Down] simul pro 10s tene; videbis codice "F1" ("SET").
- Preme clavis ad valorem currentem reprimendam, et clavis [Dun] clavis vel [Up] ut valorem mutet;
- Preme clavis [SET] ut novas notitias servet, et ad indicem menu reducas, codicem "F1" ("SET") iterum videbis.
- Vertas ad "F2" ( "HY") codice impresso [UP] clavem.
Placere referat sectionem 4.1 in forma PDF pro "ponere modum usoris interface».
Quomodo configurare Defrosting
Haec unitas per tempus et Temperaturam regat defrostionem.
- Temperatus Condition: evaporatio sensoris temperatus humilior est quam preset "defrosting Sistere temperatus" F8 (DTE)quod magnopere pertinet ne defrost.
- Tempus Conditio 1: real-time transit praesens tempus F6 (IDF)modulus regularis ad omnes fere thermostas defringendas.
- Tempus Conditio 2: Si "modum defrosting" accipias est calidum gas e contrario gyratorius compressor F10 = 1 (TDF= HTG), Compressor ultimam desinit momentum plus F5 (AC)quae est valor tutelae ad vitandum compressorem saepe startup ac sistit.
Quomodo ad terrorem externum? Dissimiles aliae thermostatae defrost, quae solum ad cubiculum sensorem referunt; hoc unitatis STC-9100 etiam monitores sensorem evaporatorem.
- Reprehendo per metum output optiones in F13 (DMO);
- Tum reprehendo infra items F14 - F19
STC-9100 Thermostat Error Code and Trouble-Sagitte
Cum atrox, recitator coruscus et stridore quiritatus, aliquam clavem urgere potes ut stridore obstrepat, sed error in ostensionis non evanescet donec omnes errores positi sunt.
- In codicibus infra significat errorem e Cella thermistoris:E01, E03, RH, RL;
- In inferioribus codicibus significat errorem a thermistoris defrost;E02, E04, EH, EL.
User Manuale STC9100 Defrost Thermostat
- Versio Anglica User Manual pro PC: User Manuale STC-9100 thermostat.pdf
- Versione Anglica Quick Guide pro Mobile: Quick Start Guide of STC-9100 thermostat.pdf
STC 9100 user manual in Russian
регулятора температуры STC-9100 - раткое руководство пользователя.pdfSTC 9100 Thermostat user manual in Spanish
Manual de usuario de Termostato STC-9100 en español.pdfIndicium: Haec institutio usoris creata ex Elitech STC-9100 Defrost Terror thermostat, non tibi persuadere possumus hoc opusculum etiam ad eadem exempla ab aliis artificibus operari.
FAQ de Haswill Foedus Panel Thermostat
- Quomodo vitare moderatores emptionis inferioris temperaturae?
hic est simplex modus, qui scientiam professio non requirit. - Quam impetro pretium?
Preme bullam inquisitionis, et formam perficies, responsum erit paucis horis. - Celsius VS Fahrenheit; et intentione
Omnes nostri digitalis temperatus moderatoris defaltam in gradibus Celsii, et pars eorum in Fahrenheit praesto est cum quantitatibus ordinis minimis;
Praeter 220V AC (± 15%), hi moderatores electronici temperaturae etiam in promptu sunt 110V AC, 12V DC, 24V DC (110/24/12 Volts). - Parameter Comparatio
Catalogue decuriae Foederis digitalis temperatus moderatoris - sarcina
Vexillum involucrum onerare potuit 100 PCS / CTN digitales temperatus moderatoris. - Accessories
Suadeamus tibi emere partes 5% ~ 10% parce ut clips et sensoriis ut truncus. - Warranty
Defectus unius anni (extensibilis) qualitatis warantia omnibus nostris moderatoribus, gratuitum of- cusationem reponendam offeremus si defectus qualitas inveniatur. - Customization Service
Si non potes aptam temperiem moderatoris huius loci invenire, adiuvabimus ut eam ex nostris proventibus maturis existentibus excolant;
Gratias Sinarum perfectae certae industriae cognatae catenae, thermostatae nostrae nativus magni pretii sunt et humilis;
the MOQ is usually from M pieces. non dubitant contact nos ad operas customizationes.
an plures quaestiones? Click FAQs
Minimum ordo moles: CC USD
Voltage
Quoad intentionem huius moderatoris electronici caliditatis
- 220V AC (± 15%) ut defaltam, Sine MOQ exigentiam ordinis minimam;
- 110V AC (± 15%) cum MOQ CC PCS;
- 12V DC cum MOQ CC PCS;
- 24v dc Sine MOQ postulatione;